开机后,出现All settings were reset to default values
开机后出现
All settings were reset to default values. The previous overclock settings have failed,system has been restored to its default settings. Press F1 to run setup. Press F2 to load default values and run setup.
翻译为:
所有设置都重置为默认值。
以前的超频设置失败,系统已恢复到其默认设置。
按F1运行安装程序。
按F2加载默认值并运行安装程序。
出现这种情况一般为以下几点:
1.内存金属条或者内存插槽脏了(手动清理下)
2.主板设置错误,没有启动项等情况(检测主板启动项,或者检查硬盘,无盘客户机检查网卡启动是否开启)
3.主板电池没电了(更换电池)
4.就是主板问题了(拿去检修吧)